Details, datasheet, quote on part number:8400001FA
 
 
Part:8400001FA
Category:Logic => Flip-Flops => D-Type Flip-Flops
Description:ti SN54ALS109A, Dual J-k Positive-edge-triggered Flip-flops With Clear And Preset
Company:Texas Instruments, Inc.
Datasheet:Download 8400001FA datasheet   File size : 116 kB
Request For quote:  Find where to buy 8400001FA
 



Datasheet text preview:
SN54ALS109A, SN54AS109A, SN74ALS109A, SN74AS109A DUAL J-K POSITIVE-EDGE-TRIGGERED FLIP-FLOPS WITH CLEAR AND PRESET
SDAS198B ­ APRIL 1982 ­ REVISED AUGUST 1995

·

Package Options Include Plastic Small-Outline (D) Packages, Ceramic Chip Carriers (FK), and Standard Plastic (N) and Ceramic (J) 300-mil DIPs
TYPICAL MAXIMUM CLOCK FREQUENCY (MHz) 50 129 TYPICAL POWER DISSIPATION PER FLIP-FLOP (mW) 6 29

SN54ALS109A, SN54AS109A . . . J PACKAGE SN74ALS109A, SN74AS109A . . . D OR N PACKAGE (TOP VIEW)

TYPE ALS109A AS109A

1CLR 1J 1K 1CLK 1PRE 1Q 1Q GND

1 2 3 4 5 6 7 8

16 15 14 13 12 11 10 9

VC C 2CLR 2J 2K 2CLK 2PRE 2Q 2Q

description
These devices contain two independent J-K positive-edge-triggered flip-flops. A low level at the preset (PRE) or clear (CLR) inputs sets or resets the outputs regardless of the levels of the other inputs. When PRE and CLR are inactive (high), data at the J and K inputs meeting the setup-time requirements are transferred to the outputs on the positive-going edge of the clock (CLK) pulse. Clock triggering occurs at a voltage level and is not directly related to the rise time of the clock pulse. Following the hold-time interval, data at the J and K inputs can be changed without affecting the levels at the outputs. These versatile flip-flops can perform as toggle flip-flops by grounding K and tying J high. They also can perform as D-type flip-flops if J and K are tied together.
SN54ALS109A, SN54AS109A . . . FK PACKAGE (TOP VIEW)

1J 1CLR NC VCC 1K 1CLK NC 1PRE 1Q
3 4 5 6 7 8

2 1 20 19 18 17 16 15

2CLR 2J 2K NC 2CLK 2PRE

14 9 10 11 12 13

NC ­ No internal connection

The SN54ALS109A and SN54AS109A are characterized for operation over the full military temperature range of ­ 55°C to 125°C. The SN74ALS109A and SN74AS109A are characterized for operation from 0°C to 70°C.
FUNCTION TABLE INPUTS PRE L H L H H H H CLR H L L H H H H CLK X X X J X X X L H L H K X X X L L H H H OUTPUTS Q H L H L Toggle Q0 Q0 L Q L H H H

H H L X X Q0 Q0 The output levels in this configuration are not specified to meet the minimum levels for VOH if the lows at PRE and CLR are near VIL maximum. Furthermore, this configuration is nonstable; that is, it does not persist when either PRE or CLR returns to its inactive (high) level.

PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.

Copyright © 1995, Texas Instruments Incorporated

POST OFFICE BOX 655303

· DALLAS, TEXAS 75265

1Q GND NC 2Q 2Q

1

SN54ALS109A, SN54AS109A, SN74ALS109A, SN74AS109A DUAL J-K POSITIVE-EDGE-TRIGGERED FLIP-FLOPS WITH CLEAR AND PRESET
SDAS198B ­ APRIL 1982 ­ REVISED AUGUST 1995

logic symbol
1PRE 1J 1CLK 1K 1CLR 2PRE 2J 2CLK 2K 2CLR 1 11 14 12 13 15 9 10 2Q 5 2 4 3 S 1J C1 1K R 7 1Q

6

1Q

2Q

This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12. Pin numbers shown are for the D, J, and N packages.

absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V Input voltage, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V Operating free-air temperature range, TA: SN54ALS109A . . . . . . . . . . . . . . . . . . . . . . . . . . . ­ 55°C to 125°C SN74ALS109A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ­ 65°C to 150°C
Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.

recommended operating conditions
SN54ALS109A MIN VCC VIH VIL IOH IOL fclock tw Supply voltage High-level input voltage Low-level input voltage High-level output current Low-level output current Clock frequency PRE or CLR low Pulse duration CLK high CLK low tsu th TA Setup time before CLK time before CLK Hold time after CLK Operating free-air temperature Data PRE or CLR inactive Data 0 15 16.5 16.5 15 10 0 ­ 55 125 4.5 2 0.7 ­ 0.4 4 30 0 15 14.5 14.5 15 10 0 0 70 ns ns °C ns NOM 5 MAX 5.5 SN74ALS109A MIN 4.5 2 0.8 ­ 0.4 8 34 NOM 5 MAX 5.5 UNIT V V V mA mA MHz

2

POST OFFICE BOX 655303

· DALLAS, TEXAS 75265

SN54ALS109A, SN54AS109A, SN74ALS109A, SN74AS109A DUAL J-K POSITIVE-EDGE-TRIGGERED FLIP-FLOPS WITH CLEAR AND PRESET
SDAS198B ­ APRIL 1982 ­ REVISED AUGUST 1995

electrical characteristics over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER VIK VOH VOL II IIH IIL CLK, J, or K PRE or CLR CLK, J, or K PRE or CLR CLK, J, or K PRE or CLR TEST CONDITIONS CONDITIONS VCC = 4.5 V, VCC = 4.5 V to 5.5 V, VCC = 4 5 V 4.5 VCC = 5 5 V 5.5 V, VCC = 5 5 V 5.5 V, VCC = 5 5 V 5.5 V, II = ­18 mA IOH = ­ 0.4 mA IOL = 4 mA IOL = 8 mA VI = 7 V VI = 2 7 V 2.7 VI = 0 4 V 0.4 MIN SN54ALS109A TYP MAX ­1.5 VCC ­ 2 0.25 0.4 0.1 0.2 20 40 ­ 0.2 ­ 0.4 VCC ­ 2 0.25 0.35 0.4 0.5 0.1 0.2 20 40 ­ 0.2 ­ 0.4 MIN SN74ALS109A TYP MAX ­1.5 UNIT V V V mA µA mA

IO VCC = 5.5 V, VO = 2.25 V ­ 20 ­112 ­ 30 ­112 mA ICC VCC = 5.5 V, See Note 1 2.4 4 2.4 4 mA All typical values are at VCC = 5 V, TA = 25°C. The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, IOS. NOTE 1: ICC is measured with J, K, CLK, and PRE grounded, then with J, K, CLK, and CLR grounded.

switching characteristics (see Figure 1)
VCC = 4.5 V to 5.5 V, CL = 50 pF, RL = 500 , TA = MIN to MAX§ SN54ALS109A MIN fmax tPLH tPHL tPLH 30 3 PRE or CLR or CLR Q or Q or 5 17 17 MAX SN74ALS109A MIN 34 3 5 5 5 13 15 16 18 MAX MHz ns ns

PARAMETER

FROM (INPUT)

TO (OUTPUT)

UNIT

5 21 CLK Q or Q or tPHL 5 20 § For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.

POST OFFICE BOX 655303

· DALLAS, TEXAS 75265

3

SN54ALS109A, SN54AS109A, SN74ALS109A, SN74AS109A DUAL J-K POSITIVE-EDGE-TRIGGERED FLIP-FLOPS WITH CLEAR AND PRESET
SDAS198B ­ APRIL 1982 ­ REVISED AUGUST 1995

absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V Input voltage, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V Operating free-air temperature range, TA: SN54AS109A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ­ 55°C to 125°C SN74AS109A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ­ 65°C to 150°C
Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.

recommended operating conditions
SN54AS109A MIN VCC VIH VIL IOH IOL fclock* tw* Supply voltage High-level input voltage Low-level input voltage High-level output current Low-level output current Clock frequency PRE or CLR low Pulse duration CLK high CLK low tsu* th* TA Setup time before CLK time before CLK Hold time after CLK Operating free-air temperature Data PRE or CLR inactive Data 0 4 4 5.5 5.5 2 0 ­ 55 125 4.5 2 0.8 ­2 20 90 0 4 4 5.5 5.5 2 0 0 70 ns ns °C ns NOM 5 MAX 5.5 SN74AS109A MIN 4.5 2 0.8 ­2 20 105 NOM 5 MAX 5.5 UNIT V V V mA mA MHz

* On products compliant to MIL-STD-883, Class B, this parameter is based on characterization data but is not production tested.

electrical characteristics over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER VIK VOH VOL II IIH IIL CLK, J, or K PRE or CLR CLK, J, or K PRE or CLR TEST CONDITIONS CONDITIONS VCC = 4.5 V, VCC = 4.5 V to 5.5 V, VCC = 4.5 V, VCC = 5.5 V, VCC = 5 5 V 5.5 V, VCC = 5 5 V 5.5 V, II = ­18 mA IOH = ­ 2 mA IOL = 20 mA VI = 7 V VI = 2 7 V 2.7 VI = 0 4 V 0.4 MIN SN54AS109A TYP MAX ­1.2 VCC ­ 2 0.25 0.5 0.1 20 40 ­ 0.5 ­1.8 VCC ­ 2 0.25 0.5 0.1 20 40 ­ 0.5 ­1.8 MIN SN74AS109A TYP MAX ­1.2 UNIT V V V mA µA mA

IO§ VCC = 5.5 V, VO = 2.25 V ­ 30 ­112 ­ 30 ­112 mA ICC VCC = 5.5 V, See Note 1 11.5 17 11.5 17 mA All typical values are at VCC = 5 V, TA = 25°C. § The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, IOS. NOTE 1: ICC is measured with J, K, CLK, and PRE grounded, then with J, K, CLK, and CLR grounded.

4

POST OFFICE BOX 655303

· DALLAS, TEXAS 75265

SN54ALS109A, SN54AS109A, SN74ALS109A, SN74AS109A DUAL J-K POSITIVE-EDGE-TRIGGERED FLIP-FLOPS WITH CLEAR AND PRESET
SDAS198B ­ APRIL 1982 ­ REVISED AUGUST 1995

switching characteristics (see Figure 1)
VCC = 4.5 V to 5.5 V, CL = 50 pF, RL = 500 , TA = MIN to MAX SN54AS109A SN74AS109A MIN fmax* tPLH tPHL tPLH 90 2 PRE or CLR or CLR Q or Q or 3.5 9 11.5 MAX MIN 105 2 3.5 8 10.5 MAX MHz ns ns

PARAMETER

FROM (INPUT)

TO (OUTPUT)

UNIT

2.5 10 2.5 9 CLK Q or Q or tPHL 3.5 10.5 3.5 9 * On products compliant to MIL-STD-883, Class B, this parameter is based on characterization data but is not production tested. For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.

POST OFFICE BOX 655303

· DALLAS, TEXAS 75265

5