Details, datasheet, quote on part number:86010012A
| |
Datasheet text preview:
SN54HCU04, SN74HCU04 HEX INVERTERS
SCLS079D MARCH 1984 REVISED AUGUST 2003
D D D
Wide Operating Voltage Range of 2 V to 6 V Outputs Can Drive Up To 10 LSTTL Loads Low Power Consumption, 20-µA Max ICC
D D D D
Typical tpd = 7 ns ±4-mA Output Drive at 5 V Low Input Current of 1 µA Max Unbuffered Outputs
SN54HCU04 . . . FK PACKAGE (TOP VIEW)
1A 1Y 2A 2Y 3A 3Y GND
1 2 3 4 5 6 7
14 13 12 11 10 9 8
VCC 6A 6Y 5A 5Y 4A 4Y
2A NC 2Y NC 3A
1Y 1A NC VCC 6A
4 5 6 7 8 3 2 1 20 19 18 17 16 15 14 9 10 11 12 13
SN54HCU04 . . . J OR W PACKAGE SN74HCU04 . . . D, DB, N, NS, OR PW PACKAGE (TOP VIEW)
6Y NC 5A NC 5Y
NC No internal connection
description/ordering information
The 'HCU04 devices contain six independent inverters. They perform the Boolean function Y = A in positive logic. ORDERING INFORMATION
TA PDIP N SOIC D 40°C to 85 C 85°C SOP NS SSOP DB TSSOP PW CDIP J 125°C 55°C to 125 C CFP W PACKAGE Tube of 25 Tube of 50 Reel of 2500 Reel of 250 Reel of 2000 Reel of 2000 Reel of 90 Reel of 2000 Reel of 250 Tube of 25 Tube of 150 ORDERABLE PART NUMBER SN74HCU04N SN74HCU04D SN74HCU04DR SN74HCU04DT SN74HCU04NSR SN74HCU04DBR SN74HCU04PW SN74HCU04PWR SN74HCU04PWT SNJ54HCU04J SNJ54HCU04W SNJ54HCU04J SNJ54HCU04W HCU04 HCU04 HU04 HCU04 TOP-SIDE MARKING SN74HCU04N
LCCC FK Tube of 55 SNJ54HCU04FK SNJ54HCU04FK Package drawings, standard packing quantities, thermal data, symbolization, and PCB design guidelines are available at www.ti.com/sc/package.
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
Copyright 2003, Texas Instruments Incorporated
On products compliant to MIL-PRF-38535, all parameters are tested unless otherwise noted. On all other products, production processing does not necessarily include testing of all parameters.
PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
POST OFFICE BOX 655303
· DALLAS, TEXAS 75265
3Y GND NC 4Y 4A
1
SN54HCU04, SN74HCU04 HEX INVERTERS
SCLS079D MARCH 1984 REVISED AUGUST 2003
FUNCTION TABLE (each inverter) INPUT A H L OUTPUT Y L H
logic diagram (positive logic)
A Y
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 V to 7 V Input clamp current, IIK (VI VCC) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA Output clamp current, IOK (VO VCC) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±25 mA Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA Package thermal impedance, JA (see Note 2): D package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86°C/W DB package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96°C/W N package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80°C/W NS package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76°C/W PW package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113°C/W Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65°C to 150°C
Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed. 2. The package thermal impedance is calculated in accordance with JESD 51-7.
recommended operating conditions (see Note 3)
SN54HCU04 MIN VCC VIH Supply voltage High-level input voltage VCC = 2 V VCC = 4.5 V VCC = 6 V VCC = 2 V VIL VI VO t/v Low-level input voltage Input voltage Output voltage Input transition rise/fall time VCC = 2 V VCC = 4.5 V VCC = 6 V VCC = 4.5 V VCC = 6 V 0 0 2 1.7 3.6 4.8 0.5 1.35 1.8 VCC VCC 1000 500 400 0 0 NOM 5 MAX 6 SN74HCU04 MIN 2 1.7 3.6 4.8 0.5 1.35 1.8 VCC VCC 1000 500 400 ns V V V V NOM 5 MAX 6 UNIT V
TA Operating free-air temperature 55 125 40 85 °C NOTE 3: All unused inputs of the device must be held at VCC or GND to ensure proper device operation. Refer to the TI application report, Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
2
POST OFFICE BOX 655303
· DALLAS, TEXAS 75265
SN54HCU04, SN74HCU04 HEX INVERTERS
SCLS079D MARCH 1984 REVISED AUGUST 2003
electrical characteristics over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS VCC 2V IOH = 20 µA A VOH VI = VCC or GND IOH = 4 mA IOH = 5.2 mA IOL = 20 µA A VOL VI = VCC or GND IOL = 4 mA IOL = 5.2 mA II ICC Ci VI = VCC or 0 VI = VCC or 0, IO = 0 4.5 V 6V 4.5 V 6V 2V 4.5 V 6V 4.5 V 6V 6V 6V 2 V to 6 V 3 MIN 1.8 4 5.5 3.98 5.48 0.2 0.5 0.5 0.26 0.26 ±100 2 10 TA = 25°C TYP MAX SN54HCU04 MIN 1.8 4 5.5 3.7 5.2 0.2 0.5 0.5 0.4 0.4 ±1000 40 10 MAX SN74HCU04 MIN 1.8 4 5.5 3.84 5.34 0.2 0.5 0.5 0.33 0.33 ±1000 20 10 nA µA pF V V MAX UNIT
switching characteristics over recommended operating free-air temperature range, CL = 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER FROM (INPUT) TO (OUTPUT) VCC 2V tpd A Y 4.5 V 6V 2V tf Y 4.5 V 6V MIN TA = 25°C TYP MAX 40 8 7 38 8 6 80 16 14 75 15 13 SN54HCU04 MIN MAX 120 24 20 110 22 19 SN74HCU04 MIN MAX 100 20 17 95 19 16 ns ns UNIT
operating characteristics, TA = 25°C
PARAMETER Cpd Power dissipation capacitance per inverter TEST CONDITIONS No load TYP 20 UNIT pF
POST OFFICE BOX 655303
· DALLAS, TEXAS 75265
3
SN54HCU04, SN74HCU04 HEX INVERTERS
SCLS079D MARCH 1984 REVISED AUGUST 2003
PARAMETER MEASUREMENT INFORMATION
From Output Under Test Test Point CL = 50 pF (see Note A) LOAD CIRCUIT In-Phase Output Input 50% tPLH 50% 10% tPHL Input 90% 90% VCC 50% 10% 0 V tf Out-of-Phase Output 90% 50% 10% tf tr is not applicable to 'HCU devices. VOLTAGE WAVEFORMS PROPAGATION DELAY AND OUTPUT TRANSITION TIMES 90% tr tPLH 50% 10% 90% 50% tPHL 90% VOH 50% 10% VOL tf VOH VCC 0V
50% 10%
VOL tr
tr VOLTAGE WAVEFORM INPUT RISE AND FALL TIMES
NOTES: A. CL includes probe and test-fixture capacitance. B. Phase relationships between waveforms were chosen arbitrarily. All input pulses are supplied by generators having the following characteristics: PRR 1 MHz, ZO = 50 , tr = 6 ns, tf = 6 ns. C. The outputs are measured one at a time with one input transition per measurement. D. tPLH and tPHL are the same as tpd.
Figure 1. Load Circuit and Voltage Waveforms
4
POST OFFICE BOX 655303
· DALLAS, TEXAS 75265
|
|