Digchip : Database on electronics components
 
Member, Distributor  
Log In
Email:
Password:


Part: CD74ACT05E

Category:
 Logic
   -> Gates
     -> Inverters Gates

Description: ti CD74ACT05, Hex Inverters With Open-drain Outputs

Company: Texas Instruments, Inc.

Datasheet: Download CD74ACT05E datasheet     File size : 283 kB

Request For quote: Find where to buy CD74ACT05E



Datasheet text preview:
CD54ACT05, CD74ACT05 HEX INVERTERS WITH OPEN-DRAIN OUTPUTS
SCHS311B ­ JANUARY 2001 ­ REVISED JUNE 2002

D D D D D D

Inputs Are TTL-Voltage Compatible Speed of Bipolar F, AS, and S, With Significantly Reduced Power Consumption Balanced Propagation Delays ±24-mA Output Drive Current ­ Fanout to 15 F Devices SCR-Latchup-Resistant CMOS Process and Circuit Design Exceeds 2-kV ESD Protection Per MIL-STD-883, Method 3015

CD54ACT05 . . . F PACKAGE CD74ACT05 . . . E OR M PACKAGE (TOP VIEW)

1A 1Y 2A 2Y 3A 3Y GND

1 2 3 4 5 6 7

14 13 12 11 10 9 8

VCC 6A 6Y 5A 5Y 4A 4Y

description
The 'ACT05 devices contain six independent inverters. These devices perform the Boolean function Y = A. The open-drain outputs require pullup resistors to perform correctly, and can be connected to other open-drain outputs to implement active-low wired-OR or active-high wired-AND functions. ORDERING INFORMATION
TA PACKAGE PDIP ­ E ­55°C to 125°C to 125°C SOIC ­ M Tube Tube Tape and reel ORDERABLE PART NUMBER CD74ACT05E CD74ACT05M CD74ACT05M96 TOP-SIDE MARKING CD74ACT05E ACT05M

CDIP ­ F Tube CD54ACT05F3A CD54ACT05F3A Package drawings, standard packing quantities, thermal data, symbolization, and PCB design guidelines are available at www.ti.com/sc/package. FUNCTION TABLE (each inverter) INPUT A H L OUTPUT Y L Z

logic diagram, each inverter (positive logic)
A Y

Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
Copyright 2002, Texas Instruments Incorporated
On products compliant to MIL-PRF-38535, all parameters are tested unless otherwise noted. On all other products, production processing does not necessarily include testing of all parameters.

PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.

POST OFFICE BOX 655303

· DALLAS, TEXAS 75265

1

CD54ACT05, CD74ACT05 HEX INVERTERS WITH OPEN-DRAIN OUTPUTS
SCHS311B ­ JANUARY 2001 ­ REVISED JUNE 2002

absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ­ 0.5 V to 6 V Input clamp current, IIK (VI VCC) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA Output clamp current, IOK (VO VCC) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±100 mA Package thermal impedance, JA (see Note 2): E package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80°C/W M package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86°C/W Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ­ 65°C to 150°C
Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed. 2. The package thermal impedance is calculated in accordance with JESD 51-7.

recommended operating conditions (see Note 3)
TA = 25°C MIN VCC VIH VIL VI VO IOH IOL t/v Supply voltage High-level input voltage Low-level input voltage Input voltage Output voltage High-level output current Low-level output current Input transition rise or fall rate 0 0 4.5 2 0.8 VCC 5.5 ­24 24 10 0 0 MAX 5.5 ­40°C TO 85°C MIN 4.5 2 0.8 VCC 5.5 ­24 24 10 0 0 MAX 5.5 ­55°C TO 125°C MIN 4.5 2 0.8 VCC 5.5 ­24 24 10 MAX 5.5 V V V V V mA mA ns/V UNIT

NOTE 3: All unused inputs of the device must be held at VCC or GND to ensure proper device operation. Refer to the TI application report, Implications of Slow or Floating CMOS Inputs, literature number SCBA004.

electrical characteristics over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS IOL = 50 µA IOL = 24 mA IOL = 50 mA IOL = 75 mA II ICC ICC Ci VI = VCC or GND VI = VCC or GND, VI = VCC ­ 2.1 V IO = 0 VCC 4.5 V 4.5 V 5.5 V 5.5 V 5.5 V 5.5 V 4.5 V to 5.5 V ±0.1 4 2.4 10 1.65 ±1 40 2.8 10 ±1 80 3 10 µA µA mA TA = 25°C MIN MAX 0.1 0.36 ­40°C TO 85°C MIN MAX 0.1 0.44 ­55°C TO 125°C MIN MAX 0.1 0.5 1.65 V UNIT

VOL

VI = VIH or VIL or

pF Test one output at a time, not exceeding 1-second duration. Measurement is made by forcing indicated current and measuring voltage to minimize power dissipation. Test verifies a minimum 50- transmission-line drive capability at 85°C and 75- transmission-line drive capability at 125°C.

2

POST OFFICE BOX 655303

· DALLAS, TEXAS 75265

CD54ACT05, CD74ACT05 HEX INVERTERS WITH OPEN-DRAIN OUTPUTS
SCHS311B ­ JANUARY 2001 ­ REVISED JUNE 2002

ACT INPUT LOAD TABLE INPUT A UNIT LOAD 0.18

Unit load is ICC limit specified in electrical characteristics table (e.g., 2.4 mA at 25°C).

switching characteristics over recommended operating free-air VCC = 5 V ± 0.5 V, CL = 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER tPZL tPLZ FROM (INPUT) TO (OUTPUT)

temperature
­55°C TO 125°C MIN 2.3 2.7 MAX 9.3 10.8

range,

­40°C TO 85°C MIN MAX 8.5 9.8 2.4 2.8

UNIT

A or B or

Y

ns

operating characteristics, VCC = 5 V, TA = 25°C
PARAMETER Cpd Power dissipation capacitance TYP 105 UNIT pF

PARAMETER MEASUREMENT INFORMATION
R1 = 500 S1 2 × VCC VCC Input R2 = 500 tPZL Output When VCC = 1.5 V, R1 = R2 = 1 k LOAD CIRCUIT 50% VCC tPLZ VCC 20% VCC VOL 50% VCC 50% VCC 0V

From Output Under Test CL = 50 pF (see Note A)

VOLTAGE WAVEFORMS PROPAGATION DELAY TIMES

NOTES: A. CL includes probe and jig capacitance. B. All input pulses are supplied by generators having the following characteristics: PRR 1 MHz, ZO = 50 , tr 3 ns, tf 3 ns. C. The outputs are measured one at a time with one input transition per measurement.

Figure 1. Load Circuit and Voltage Waveforms

POST OFFICE BOX 655303

· DALLAS, TEXAS 75265

3

IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI's terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI's standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third­party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements.

Mailing Address: Texas Instruments Post Office Box 655303 Dallas, Texas 75265

Copyright 2002, Texas Instruments Incorporated




Others parts begin by cd
CD-1   CD-2   CD-3   CD-4   CD-5   CD-6   CD-7   CD-8   CD-9   CD-10   CD-11   CD-12   CD-13   CD-14   CD-15   CD-16   CD-17   CD-18   CD-19   CD-20   CD-21   CD-22   CD-23   CD-24   CD-25   CD-26   CD-27   CD-28   CD-29   CD-30   CD-31   CD-32   CD-33   CD-34   CD-35   CD-36   CD-37