Details, datasheet, quote on part number:LM2903PW
| |
| Part: | LM2903PW |
| Category: | Analog & Mixed-Signal Processing => Amplifiers => Differential Amplifiers |
| Description: | Dual Differential Comparators |
| Company: | Texas Instruments, Inc. |
| Datasheet: | Download LM2903PW datasheet File size : 103 kB |
| Request For quote: | Find where to buy LM2903PW
|
| |
Datasheet text preview:
LM193, LM293, LM293A, LM393 LM393A, LM393Y, LM2903, LM2903Q DUAL DIFFERENTIAL COMPARATORS
SLCS005E JUNE 1976 REVISED NOVEMBER 1999
D D D D D D D D D D
Single Supply or Dual Supplies Wide Range of Supply Voltage . . . 2 V to 36 V Low Supply-Current Drain Independent of Supply Voltage . . . 0.4 mA Typ Per Comparator Low Input Bias Current . . . 25 nA Typ Low Input Offset Current . . . 3 nA Typ (LM193) Low Input Offset Voltage . . . 2 mV Typ Common-Mode Input Voltage Range Includes Ground Differential Input Voltage Range Equal to Maximum-Rated Supply Voltage . . . ±36 V Low Output Saturation Voltage Output Compatible With TTL, MOS, and CMOS
D, JG, P, OR PW PACKAGE (TOP VIEW)
1OUT 1IN 1IN+ GND
1 2 3 4
8 7 6 5
VCC 2OUT 2IN 2IN+
FK PACKAGE (TOP VIEW)
NC 1OUT NC VCC NC NC 1IN NC 1IN+ NC
32 4 5 6 7 8 1 20 19 18 17 16 15 14 9 10 11 12 13
NC 2OUT NC 2IN NC
These devices consist of two independent voltage NC No internal connection comparators that are designed to operate from a single power supply over a wide range of voltages. Operation from dual supplies also is possible as long as the difference between the two supplies is 2 V to 36 V, and VCC is at least 1.5 V more positive than the input common-mode voltage. Current drain is independent of the supply voltage. The outputs can be connected to other open-collector outputs to achieve wired-AND relationships. The LM193 is characterized for operation from 55°C to 125°C. The LM293 and LM293A are characterized for operation from 25°C to 85°C. The LM393 and LM393A are characterized for operation from 0°C to 70°C. The LM2903 and LM2903Q are characterized for operation from 40°C to 125°C and are manufactured to demanding automotive requirements.
logic diagram (each comparator)
IN+ IN OUT
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
Copyright © 1999, Texas Instruments Incorporated
POST OFFICE BOX 655303
· DALLAS, TEXAS 75265
NC GND NC 2IN+ NC
description
1
LM193, LM293, LM293A, LM393 LM393A, LM393Y, LM2903, LM2903Q DUAL DIFFERENTIAL COMPARATORS
SLCS005E JUNE 1976 REVISED NOVEMBER 1999
AVAILABLE OPTIONS PACKAGED DEVICES TA VIO(max) AT 25°C 5 mV 2 mV 5 mV 2 mV 7 mV mV SMALL OUTLINE (D) LM393D LM393AD LM293D LM293AD LM2903D LM2903QD CHIP CARRIER (FK) -- -- -- -- -- -- CERAMIC DIP (JG) -- -- -- -- -- -- PLASTIC DIP (P) LM393P LM393AP LM293P LM293AP LM2903P LM2903QP TSSOP (PW) LM393PW -- -- -- LM2903PW -- -- CHIP FORM (Y)§ LM393Y -- -- -- -- -- --
0°C to 70°C to 70°C 25°C to 85°C to 85°C 40°C to 125°C to 125°C
55°C to 125°C 5 mV LM193D LM193FK LM193JG LM193P The D package is available taped and reeled. Add the suffix R (e.g., LM393DR). The PW package is only available left-end taped and reeled (e.g., LM393PWR). § Chips are tested at 25°C (see LM393Y for electrical characteristics).
schematic (each comparator)
80-µA Current Regulator VCC
10 µA
60 µA
10 µA
80 µA
COMPONENT COUNT Epi-FET Diodes Resistors Transistors 1 2 2 30
IN+
OUT
IN
GND Current values shown are nominal.
2
POST OFFICE BOX 655303
· DALLAS, TEXAS 75265
LM193, LM293, LM293A, LM393 LM393A, LM393Y, LM2903, LM2903Q DUAL DIFFERENTIAL COMPARATORS
SLCS005E JUNE 1976 REVISED NOVEMBER 1999
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, VCC (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 V Differential input voltage, VID (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±36 V Input voltage range, VI (either input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.3 V to 36 V Output voltage, VO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 V Output current, IO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 mA Duration of output short-circuit to ground (see Note 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Unlimited Continuous total power dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See Dissipation Rating Table Package thermal impedance, JA (see Note 4): D package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97°C/W P package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85°C/W PW package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149°C/W Case temperature for 60 seconds: FK package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds: D, P, or PW package . . . . . . . . . . . . 260°C Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds: JG package . . . . . . . . . . . . . . . . . . . . 300°C Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65°C to 150°C
Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTES: 1. All voltage values, except differential voltages, are with respect to the network ground. 2. Differential voltages are at IN+ with respect to IN. 3. Short circuits from outputs to VCC can cause excessive heating and eventual destruction. 4. The package thermal impedance is calculated in accordance with JESD 51. DISSIPATION RATING TABLE PACKAGE FK JG TA 25°C POWER RATING 900 mW 900 mW DERATING FACTOR 11.0 mW/°C 8.4 mW/°C DERATE ABOVE TA 68°C 43°C TA = 70°C POWER RATING 880 mW 672 mW TA = 85°C POWER RATING 715 mW 546 mW TA = 125°C POWER RATING 275 mW 210 mW
POST OFFICE BOX 655303
· DALLAS, TEXAS 75265
3
|
|