Digchip : Database on electronics components
Electronic components database
Search:                      In section:
Member, Distributor  
Log In
Email:
Password:


Part: PT4144C

Category:
 Power Management
             -> Plug-in Power Solutions->Isolated->Single Output

Description: ti PT4144, 15V, 1.3A 20W ISOlated DC-DC Converter

Company: Texas Instruments, Inc.

Datasheet: Download PT4144C datasheet     File size : 157 kB

Request For quote: Find where to buy PT4144C



Datasheet text preview:
PT4140 Series
20-W 24-V Input Isolated DC/DC Converter
SLTS120B
(Revised 3/1/2002)
Features
· Input Voltage Range: 18V to 40V · 20W Rated · 82% Efficiency · 1500 VDC Isolation · Low Profile (8.5 mm) · Small Footprint: 1.52in x 1.73in · Remote On/Off · · · · · · · Short Circuit Protection Over Temperature Shutdown Under-Voltage Lockout UL1950 Recognized CSA 22.2 950 Certified EN60950 Approved 4×106 Hrs MTBF
Description
The PT4140 power modules are a series of isolated DC/DC converters housed in a low-profile package. Rated for 20 watts or 5A, the series includes standard output voltages ranging from as low as 1.5VDC to 15VDC. The output may be adjusted up to ±10% of nominal. These converters are ideal for Telecom, Industrial, Computer, and other distributed power applications that require i n p u t - t o - o u t p u t isolation. Using multiple PT4140 modules, system designers can implement a complete custom power supply solution. The flexibility of full isolation also allows the input or output to be configured for negative voltage operation. The PT4140 series requires no additional components for proper operation.
Ordering Information
PT 4141H PT 4142H PT 4143H PT 4144H PT 4146H PT 4147H PT 4148H = 3.3V/5A = 5.0V/4A = 12.0V/16A = 15.0V/13A = 1.5V/5A = 1.8V/5A = 2.5V/5A (16.5W)
Pin-Out Information
Pin
1 2 3 4 5 6
Function
Remote On/Off ­Vin +Vin ­Vout +Vout Vout Adjust
(7.5W) (9W) (12.5W)
For further information, see application notes.
PT Series Suffix (PT1234x )
Case/Pin Configuration Horizontal SMD Order Suffix Package Code * (EGD) (EGE)
A C
* Previously known as package style 710. (Reference the applicable package code drawing for the dimensions and PC board layout)
Standard Application
+VIN ­VIN
3
5
+VOUT
LOAD
PT4140
2 4 1 6
­VOUT
Remote On/Off
Q1 BSS138
VOAdj
For technical support and more information, see inside back cover or visit www.ti.com
PT4140 Series
20-W 24-V Input Isolated DC/DC Converter
Specifications
Characteristic Output Current
(Unless otherwise stated, Ta =25°C, V in =24V, Cout =0µF, and Io =Io max) Symbol Io Conditions Over Vin range Vo = 15V Vo = 12V Vo =5.0V Vo 3.3V Vo 5.0V Vo 3.3V ­40° Ta +85°C Over Vin range Over Io range Includes set-point, line load, ­40° Ta +85°C Vo 5.0V Vo 3.3V Vo 5.0V Vo 3.3V Vo 5.0V Vo 3.3V Vo = 15V Vo = 12V Vo =5.0V Vo =3.3V Vo =1.8V Vo 5.0V Vo 3.3V Min 0.1 (1) 0.1 (1) 0.1 (1) 0.1 (1) 18.0 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 600 800 -- 2.5 ­0.2 -- -- -- 0 1500 -- 10 -40 -40 4.0 -- -- --
PT4140 SERIES Typ Max
-- -- -- -- 24.0 ±1 -- ±0.5 ±0.2 ±7 ±0.4 ±13 ±2 ±67 86 83 82 78 67 0.5 15 100 ±3.0 ±150 2xIomax 650 850 15 -- -- ­10 7 1.0 -- -- 1100 -- -- -- -- 500 15 23 1.3 1.6 4.0 5.0 40.0 ±1.5 ±50 -- ±1.0 ±33 ±1.0 ±33 -- -- -- -- -- -- -- -- -- -- -- -- -- 700 900 -- 7.0 (2) +0.8 ­ 50 -- 200 -- -- -- +85 (3) +125 -- -- -- --
Units A VDC %Vo mV %Vo %Vo mV %Vo mV %Vo mV % %Vo mVpp µs %Vo mV A kHz V V µA mA µF µF V pF M °C °C 106 Hrs G's G's grams
Input Voltage Range Set Point Voltage T lerance o Temperature Variation Line Regulation Load Regulation Total Output Voltage Variation Efficiency
Vin Vo tol Regtemp Regline Regload Votot
Over Io Range
Vo Ripple (pk-pk) Transient Response
Vr ttr Vtr
20MHz bandwidth
0.1A/µs, load step 50% to 100% Iomax Vo over/undershoot Vo 5.0V Vo 3.3V Over Vin range Vo 12.0V Vo 5.0V
Short Circuit Current Switching Frequency Under-Voltage Lockout Remote On/Off (Pin 1) Input High Voltage Input Low Voltage Input Low Current Standby Input Current Internal Input Capacitance External Output Capacitance Isolation Voltage Capacitance Resistance Operating T mperature Range e Storage T mperature e Reliability Mechanical Shock Mechanical Vibration Weight Flammability
Isc s UVLO VIH VIL IIL Iin standby Cin Cout
Referenced to ­Vin (pin 2)
pins 1 & 2 connected Between +Vo and ­Vo Input to output Over Vin range -- Per Bellcore TR-332 50% stress, Ta =40°C, ground benign Per Mil-Std-883D, method 2002.3, 1mS, half-sine, mounted to a fixture Per Mil-Std-883D, method 2007.2, 20-2000Hz, soldered in a PC board -- Materials meet UL 94V-0
Ta Ts MTBF -- -- -- --
Notes: (1) The DC/DC converter will operate at no load with reduced specifications. (2) The Remote On/Off (pin 1) has an internal pull-up, and if it is left open circuit the module will operate when input power is applied. Refer to the application notes for interface considerations. (3) See Safe Operating Area curves or contact the factory for the appropriate derating.
For technical support and more information, see inside back cover or visit www.ti.com
PT4140 Series
20-W 24-V Input Isolated DC/DC Converter
PT4141, 3.3 VDC
(See Note A)
PT4142, 5.0 VDC
(See Note A)
PT4143, 12.0 VDC
(See Note A)
Efficiency vs Output Current
90 90
Efficiency vs Output Current
90
Efficiency vs Output Current
Efficiency - %
Efficiency - %
Vin
18.0V 24.0V 36.0V
Vin
18.0V 24.0V 36.0V
Efficiency - %
80
80
80
Vin
18.0V 24.0V 36.0V
70
70
70
60
60
60
50 0 1 2 3 4 5
50 0 1 2 3 4
50 0 0. 4 0. 8 1. 2 1. 6
Iout (A)
Iout (A)
Iout (A)
Ripple vs Output Current
20 20 15 15
Ripple vs Output Current
40
Ripple vs Output Current
Ripple - mV
Ripple - mV
Ripple - mV
Vin
36.0V 24.0V 18.0V
Vin
36.0V 24.0V 18.0V
30
Vin
36.0V 24.0V 18.0V
10
10
20
5
5
10
0 0 1 2 3 4 5
0 0 1 2 3 4
0 0 0.4 0.8 1.2 1.6
Iout (A)
Iout (A)
Iout (A)
Power Dissipation vs Output Current
5
Power Dissipation vs Output Current
5 4 5 4
Power Dissipation vs Output Current
4
Pd - Watts
Pd - Watts
3
2
36.0V 24.0V 18.0V
3 2 1 0
Pd - Watts
Vin
Vin
36.0V 24.0V 18.0V
Vin
3 2 1 0
36.0V 24.0V 18.0V
1
0 0 1 2 3 4 5
0
1
2
3
4
0
0. 4
0. 8
1. 2
1. 6
Iout (A)
Iout (A)
Iout (A)
Safe Operating Area, Vin =48V (See Note B)
90
Safe Operating Area, Vin =48V (See Note B)
90
Safe Operating Area, Vin =48V (See Note B)
90
Ambient Temperature (°C)
Ambient Temperature (°C)
70 60 50 40 30 20 0 1 2 3 4 5
Airflow 20 0LFM 12 0LFM 60 LFM Nat conv
70 60 50 40 30 20 0 1 2 3 4
Airf low 200 LFM 120 LFM 60LFM Nat conv
Ambient Temperature (°C)
80
80
80 70 60 50 40 30 20 0 0.25 0.5 0.75 1 1.25 1.5 1.75
Airf low 200 LFM 120 LFM 60LFM Nat conv
Iout (A)
Iout (A)
Iout (A)
Note A: Characteristic data has been developed from actual products tested at 25°C. This data is considered typical data for the Converter. Note B: SOA curves represent the conditions at which internal components are at or below the manufacturer's maximum operating temperatures
For technical support and more information, see inside back cover or visit www.ti.com


Others parts begin by pt
PT-1   PT-2   PT-3   PT-4   PT-5   PT-6   PT-7   PT-8   PT-9   PT-10   PT-11   PT-12   PT-13   PT-14   PT-15   PT-16   PT-17   PT-18   PT-19   PT-20   PT-21   PT-22   PT-23   PT-24   PT-25   PT-26   PT-27   PT-28   PT-29   PT-30   PT-31   PT-32