Details, datasheet, quote on part number:SN54LVU04
| |
Datasheet text preview:
SN54LVU04, SN74LVU04 HEX INVERTERS
SCLS185B FEBRUARY 1993 REVISED APRIL 1996
D D D D D D
EPIC TM (Enhanced-Performance Implanted CMOS) 2-µ Process Typical VOLP (Output Ground Bounce) 2 V at VCC, TA = 25°C ESD Protection Exceeds 2000 V Per MIL-STD-883C, Method 3015; Exceeds 200 V Using Machine Model (C = 200 pF, R = 0) Latch-Up Performance Exceeds 250 mA Per JEDEC Standard JESD-17 Package Options Include Plastic Small-Outline (D), Shrink Small-Outline (DB), Thin Shrink Small-Outline (PW), and Ceramic Flat (W) Packages, Ceramic Chip Carriers (FK), and Ceramic (J) 300-mil DIPs
SN54LVU04 . . . J OR W PACKAGE SN74LVU04 . . . D, DB, OR PW PACKAGE (TOP VIEW)
1A 1Y 2A 2Y 3A 3Y GND
1 2 3 4 5 6 7
14 13 12 11 10 9 8
VCC 6A 6Y 5A 5Y 4A 4Y
SN54LVU04 . . . FK PACKAGE (TOP VIEW)
1Y 1A NC VCC 6A 2A NC 2Y NC 3A
4 5 6 7 8 3 2 1 20 19 18 17 16 15 14 9 10 11 12 13
description
These hex inverters are designed for 2.7-V to 5.5-V VCC operation. The 'LVU04 contain six independent inverters with unbuffered outputs. These devices perform the Boolean function Y = A. The SN74LVU04 is available in TI's shrink small-outline package (DB), which provides the same I/O pin count and functionality of standard small-outline packages in less than half the printed-circuit-board area.
6Y NC 5A NC 5Y
NC No internal connection
The SN54LVU04 is characterized for operation over the full military temperature range of 55°C to 125°C. The SN74LVU04 is characterized for operation from 40°C to 85°C.
FUNCTION TABLE (each inverter) INPUT A H L OUTPUT Y L H
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. EPIC is a trademark of Texas Instruments Incorporated.
UNLESS OTHERWISE NOTED this document contains PRODUCTION DATA information current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. POST OFFICE BOX 655303
Copyright © 1996, Texas Instruments Incorporated
· DALLAS, TEXAS 75265
3Y GND NC 4Y 4A
1
SN54LVU04, SN74LVU04 HEX INVERTERS
SCLS185B FEBRUARY 1993 REVISED APRIL 1996
logic symbol
1A 2A 3A 4A 5A 6A 1 3 5 9 11 13 1 2 4 6 8 10 12 1Y 2Y 3Y 4Y 5Y 6Y
logic diagram, each inverter (positive logic)
A Y
This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12. Pin numbers shown are for D, DB, J, PW and W packages.
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 V to 7 V Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 V to VCC + 0.5 V Output voltage range, VO (see Notes 1 and 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 V to VCC + 0.5 V Input clamp current, IIK (VI VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 mA Output clamp current, IOK (VO VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 25 mA Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA Maximum power dissipation at TA = 55°C (in still air) (see Note 3): D package . . . . . . . . . . . . . . . . . . . 1.25 W DB or PW package . . . . . . . . . . . . . 0.5 W Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65°C to 150°C
Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stressratings only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed. 2. This value is limited to 7 V maximum. 3. The maximum package power dissipation is calculated using a junction temperature of 150°C and a board trace length of 750 mils.
recommended operating conditions (see Note 4)
SN54LVU04 MIN VCC VIH VIL VI VO IOH IOL t /v Supply voltage High-level input voltage input voltage Low-level input voltage input voltage Input voltage Output voltage High-level output current output current Low-level output current output current Input transition rise or fall rate VCC = 2.7 V to 3.6 V VCC = 4.5 V to 5.5 V VCC = 2.7 V to 3.6 V VCC = 4.5 V to 5.5 V 0 55 VCC = 2.7 V to 3.6 V VCC = 4.5 V to 5.5 V VCC = 2.7 V to 3.6 V VCC = 4.5 V to 5.5 V 0 0 2.7 2.4 3.55 0.5 0.8 VCC VCC 6 12 6 12 100 125 0 40 0 0 MAX 5.5 SN74LVU04 MIN 2.7 2.4 3.55 0.5 0.8 VCC VCC 6 12 6 12 100 85 MAX 5.5 UNIT V V V V V mA mA ns / V °C
TA Operating free-air temperature NOTE 4: Unused inputs must be held high or low to prevent them from floating.
PRODUCT PREVIEW information concerns products in the formative or design phase of development. Characteristic data and other specifications are design goals. Texas Instruments reserves the right to change or discontinue these products without notice.
2
POST OFFICE BOX 655303
· DALLAS, TEXAS 75265
SN54LVU04, SN74LVU04 HEX INVERTERS
SCLS185B FEBRUARY 1993 REVISED APRIL 1996
electrical characteristics over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER VI = VIL, VI = GND, VI = GND, VI = VIH, VOL VI = VCC, VI = VCC, VI = VCC or GND or GND VI = VCC or GND, or GND IO = 0 TEST CONDITIONS CONDITIONS IOH = 100 µA IOH = 6 mA IOH = 12 mA IOL = 100 µA IOL = 6 mA IOL = 12 mA VCC MIN to MAX 3V 4.5 V MIN to MAX 3V 4.5 V 3.6 V 5.5 V 3.6 V 5.5 V 3 V to 3.6 V 3.3 V 5V 7 7.5 SN54LVU04 MIN VCC 0.5 2.4 3.6 0.5 0.4 0.55 ±1 ±1 20 20 500 7 7.5 TYP MAX SN74LVU04 MIN VCC 0.5 2.4 3.6 0.5 0.4 0.55 ±1 ±1 20 20 500 µA µA µA pF V TYP MAX UNIT
VOH
V
II ICC
nICC
Ci
One input at VCC 0.6 V, Other inputs at VCC or GND VI = VCC or GND or GND
For conditions shown as MIN or MAX, use the appropriate values under recommended operating conditions.
switching characteristics over recommended operating free-air temperature range, CL = 50 pF (unless otherwise noted) (see Figure 1)
SN54LVU04 PARAMETER tpd FROM (INPUT) A TO (OUTPUT) Y VCC = 5 V ± 0.5 V MIN TYP MAX 5 10 VCC = 3.3 V ± 0.3 V MIN TYP MAX 8 13 VCC = 2.7 V MIN MAX 13 UNIT
ns
switching characteristics over recommended operating free-air temperature range, CL = 50 pF (unless otherwise noted) (see Figure 1)
SN74LVU04 PARAMETER tpd FROM (INPUT) A TO (OUTPUT) Y VCC = 5 V ± 0.5 V MIN TYP MAX 5 10 VCC = 3.3 V ± 0.3 V MIN TYP MAX 8 13 VCC = 2.7 V MIN MAX 13 UNIT
ns
operating characteristics, TA = 25°C
PARAMETER Cpd Power dissipation capacitance per inverter dissi ca er inverter TEST CONDITIONS CL = 50 pF 50 F, f = 10 MHz 10 MHz 5V 12 VCC 3.3 V TYP 7 pF UNIT
PRODUCT PREVIEW information concerns products in the formative or design phase of development. Characteristic data and other specifications are design goals. Texas Instruments reserves the right to change or discontinue these products without notice.
POST OFFICE BOX 655303
· DALLAS, TEXAS 75265
3
|
|