SN54HC04, SN74HC04 HEX INVERTERS
SCLS078B DECEMBER 1982 REVISED MAY 1997
D
Package Options Include Plastic Small-Outline (D), Shrink Small-Outline (DB), Thin Shrink Small-Outline (PW), and Ceramic Flat (W) Packages, Ceramic Chip Carriers (FK), and Standard Plastic (N) and Ceramic (J) 300-mil DIPs
SN54HC04 . . . J OR W PACKAGE SN74HC04 . . . D, DB, N, OR PW PACKAGE (TOP VIEW)
description
These devices contain six independent inverters. They perform the Boolean function Y = A in positive logic. The SN54HC04 is characterized for operation over the full military temperature range of 55°C to 125°C. The SN74HC04 is characterized for operation from 40°C to 85°C.
FUNCTION TABLE (each inverter) INPUT A H L OUTPUT Y L H
1A 1Y 2A 2Y 3A 3Y GND
1 2 3 4 5 6 7
14 13 12 11 10 9 8
VCC 6A 6Y 5A 5Y 4A 4Y
SN54HC04 . . . FK PACKAGE (TOP VIEW)
1Y 1A NC VCC 6A 2A NC 2Y NC 3A
4 5 6 7 8 3 2 1 20 19 18 17 16 15 14 9 10 11 12 13
6Y NC 5A NC 5Y
logic symbol
1A 2A 3A 4A 5A 6A 1 3 5 9 11 13 1 2 4 6 8 10 12 1Y 2Y 3Y 4Y 5Y 6Y
NC No internal connection
This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12. Pin numbers shown are for the D, DB, J, N, PW, and W packages.
logic diagram (positive logic)
A Y
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
Copyright © 1997, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
POST OFFICE BOX 655303
· DALLAS, TEXAS 75265
3Y GND NC 4Y 4A
1
SN54HC04, SN74HC04 HEX INVERTERS
SCLS078B DECEMBER 1982 REVISED MAY 1997
absolute maximum ratings over operating free-air temperature range
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 V to 7 V Input clamp current, IIK (VI VCC) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA Output clamp current, IOK (VO VCC) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±25 mA Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA Package thermal impedance, JA (see Note 2): D package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127°C/W DB package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158°C/W N package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78°C/W PW package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170°C/W Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65°C to 150°C
Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed. 2. The package thermal impedance is calculated in accordance with JESD 51, except for through-hole packages, which use a trace length of zero.
recommended operating conditions
SN54HC04 MIN VCC VIH Supply voltage High-level input voltage VCC = 2 V VCC = 4.5 V VCC = 6 V VCC = 2 V VIL VI VO tt TA Low-level input voltage Input voltage Output voltage Input transition (rise and fall) time Operating free-air temperature VCC = 2 V VCC = 4.5 V VCC = 6 V VCC = 4.5 V VCC = 6 V 2 1.5 3.15 4.2 0 0 0 0 0 0 0 0 55 0.5 1.35 1.8 VCC VCC 1000 500 400 125 NOM 5 MAX 6 SN74HC04 MIN 2 1.5 3.15 4.2 0 0 0 0 0 0 0 0 40 0.5 1.35 1.8 VCC VCC 1000 500 400 85 °C ns V V V V NOM 5 MAX 6 UNIT V
2
POST OFFICE BOX 655303
· DALLAS, TEXAS 75265
SN54HC04, SN74HC04 HEX INVERTERS
SCLS078B DECEMBER 1982 REVISED MAY 1997
electrical characteristics over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS CONDITIONS VCC 2V IOH = 20 µA VOH VI = VIH or VIL IOH = 4 mA IOH = 5.2 mA IOL = 20 µA VOL VI = VIH or VIL IOL = 4 mA IOL = 5.2 mA II ICC Ci VI = VCC or 0 VI = VCC or 0, IO = 0 4.5 V 6V 4.5 V 6V 2V 4.5 V 6V 4.5 V 6V 6V 6V 2 V to 6 V 3 MIN 1.9 4.4 5.9 3.98 5.48 TA = 25°C TYP MAX 1.998 4.499 5.999 4.3 5.8 0.002 0.001 0.001 0.17 0.15 ±0.1 0.1 0.1 0.1 0.26 0.26 ±100 2 10 SN54HC04 MIN 1.9 4.4 5.9 3.7 5.2 0.1 0.1 0.1 0.4 0.4 ±1000 40 10 MAX SN74HC04 MIN 1.9 4.4 5.9 3.84 5.34 0.1 0.1 0.1 0.33 0.33 ±1000 20 10 nA µA pF V V MAX UNIT
switching characteristics over recommended operating free-air temperature range, CL = 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER FROM (INPUT) TO (OUTPUT) VCC 2V tpd A Y 4.5 V 6V 2V tt Y 4.5 V 6V MIN TA = 25°C TYP MAX 45 9 8 38 8 6 95 19 16 75 15 13 SN54HC04 MIN MAX 145 29 25 110 22 19 SN74HC04 MIN MAX 120 24 20 95 19 16 ns ns UNIT
operating characteristics, TA = 25°C
PARAMETER Cpd Power dissipation capacitance per inverter TEST CONDITIONS No load TYP 20 UNIT pF
POST OFFICE BOX 655303
· DALLAS, TEXAS 75265
3
|
|