Details, datasheet, quote on part number:SN74HC05
| |
| Part: | SN74HC05 |
| Category: | Logic => Buffers/Inverters => 2-State => CMOS/BiCMOS->HC/HCT Family |
| Description: | Hex Inverter/buffer With Open Collector Outputs |
| Company: | Texas Instruments, Inc. |
| Datasheet: | Download SN74HC05 datasheet File size : 241 kB |
| Request For quote: | Find where to buy SN74HC05
|
| |
Datasheet text preview:
SN54HC05, SN74HC05 HEX INVERTERS WITH OPEN-DRAIN OUTPUTS
SCLS080C MARCH 1984 REVISED NOVEMBER 2002
D D D
Wide Operating Voltage Range of 2 V to 6 V Outputs Can Drive Up to 10 LSTTL Loads Low Power Consumption, 20-µA Max ICC
D D D
Typical tpd = 8 ns ±4-mA Output Drive at 5 V Low Input Current of 1 µA Max
SN54HC05 . . . FK PACKAGE (TOP VIEW)
1A 1Y 2A 2Y 3A 3Y GND
1 2 3 4 5 6 7
14 13 12 11 10 9 8
VCC 6A 6Y 5A 5Y 4A 4Y
1Y 1A NC VCC 6A 2A NC 2Y NC 3A
4 5 6 7 8 3 2 1 20 19 18 17 16 15 14 9 10 11 12 13
SN54HC05 . . . J OR W PACKAGE SN74HC05 . . . D, DB, N, NS, OR PW PACKAGE (TOP VIEW)
6Y NC 5A NC 5Y
NC No internal connection
description/ordering information
The 'HC05 devices contain six independent inverters. They perform the Boolean function Y = A in positive logic. The open-drain outputs require pullup resistors to perform correctly. They may be connected to other open-drain outputs to implement active-low wired-OR or active-high wired-AND functions. ORDERING INFORMATION
TA PDIP N SOIC D to 85°C 40°C to 85°C SOP NS SSOP DB TSSOP PW CDIP J 55°C to 125°C CFP W LCCC FK PACKAGE Tube Tube Tape and reel Tape and reel Tape and reel Tape and reel Tube Tube Tube ORDERABLE PART NUMBER SN74HC05N SN74HC05D SN74HC05DR SN74HC05NSR SN74HC05DBR SN74HC05PWR SNJ54HC05J SNJ54HC05W SNJ54HC05FK TOP-SIDE MARKING SN74HC05N HC05 HC05 HC05 HC05 SNJ54HC05J SNJ54HC05W
SNJ54HC05FK Package drawings, standard packing quantities, thermal data, symbolization, and PCB design guidelines are available at www.ti.com/sc/package. FUNCTION TABLE (each inverter) INPUT A H L OUTPUT Y L H
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
Copyright 2002, Texas Instruments Incorporated
On products compliant to MIL-PRF-38535, all parameters are tested unless otherwise noted. On all other products, production processing does not necessarily include testing of all parameters.
PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
POST OFFICE BOX 655303
· DALLAS, TEXAS 75265
3Y GND NC 4Y 4A
1
SN54HC05, SN74HC05 HEX INVERTERS WITH OPEN-DRAIN OUTPUTS
SCLS080C MARCH 1984 REVISED NOVEMBER 2002
logic diagram (positive logic)
A Y
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 V to 7 V Input clamp current, IIK (VI VCC) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA Output clamp current, IOK (VO VCC) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±25 mA Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA Package thermal impedance, JA (see Note 2): D package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86°C/W DB package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96°C/W N package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80°C/W NS package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76°C/W PW package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113°C/W Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65°C to 150°C
Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed. 2. The package thermal impedance is calculated in accordance with JESD 51-7.
recommended operating conditions (see Note 3)
SN54HC05 MIN VCC VIH Supply voltage High-level input voltage VCC = 2 V VCC = 4.5 V VCC = 6 V VCC = 2 V VIL VI VO t/v Low-level input voltage Input voltage Output voltage Input transition rise/fall time VCC = 2 V VCC = 4.5 V VCC = 6 V VCC = 4.5 V VCC = 6 V 0 0 2 1.5 3.15 4.2 0.5 1.35 1.8 VCC VCC 1000 500 400 0 0 NOM 5 MAX 6 SN74HC05 MIN 2 1.5 3.15 4.2 0.5 1.35 1.8 VCC VCC 1000 500 400 ns V V V V NOM 5 MAX 6 UNIT V
TA Operating free-air temperature 55 125 40 85 °C NOTE 3: All unused inputs of the device must be held at VCC or GND to ensure proper device operation. Refer to the TI application report, Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
2
POST OFFICE BOX 655303
· DALLAS, TEXAS 75265
SN54HC05, SN74HC05 HEX INVERTERS WITH OPEN-DRAIN OUTPUTS
SCLS080C MARCH 1984 REVISED NOVEMBER 2002
electrical characteristics over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER IOH TEST CONDITIONS CONDITIONS VI = VIH or VIL, VO = VCC IOL = 20 µA VOL VI = VIH or VIL IOL = 4 mA IOL = 5.2 mA II ICC Ci VI = VCC or 0 VI = VCC or 0, IO = 0 VCC 6V 2V 4.5 V 6V 4.5 V 6V 6V 6V 2 V to 6 V 3 MIN TA = 25°C TYP MAX 0.01 0.002 0.001 0.001 0.17 0.15 ±0.1 0.5 0.1 0.1 0.1 0.26 0.26 ±100 2 10 SN54HC05 MIN MAX 10 0.1 0.1 0.1 0.4 0.4 ±1000 40 10 SN74HC05 MIN MAX 5 0.1 0.1 0.1 0.33 0.33 ±1000 20 10 nA µA pF V UNIT µA
switching characteristics over recommended operating free-air temperature range, CL = 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER FROM (INPUT) TO (OUTPUT) VCC 2V tPLH A Y 4.5 V 6V 2V tPHL A Y 4.5 V 6V 2V tf Y 4.5 V 6V TA = 25°C MIN TYP MAX 60 13 10 45 9 8 38 8 6 115 23 20 85 17 14 75 15 13 SN54HC05 MIN MAX 175 35 30 130 26 22 110 22 19 SN74HC05 MIN MAX 145 29 25 105 21 18 95 19 16 ns ns ns UNIT
operating characteristics, TA = 25°C
PARAMETER Cpd Power dissipation capacitance per inverter TEST CONDITIONS No load TYP 20 UNIT pF
POST OFFICE BOX 655303
· DALLAS, TEXAS 75265
3
|
|