uA748C, uA748M GENERAL-PURPOSE OPERATIONAL AMPLIFIERS
SLOS095 ­ D921, DECEMBER 1970 ­ REVISED OCTOBER 1990
· · · · · · ·
Frequency and Transient Response Characteristics Adjustable Short-Circuit Protection Offset-Voltage Null Capability Wide Common-Mode and Differential Voltage Ranges Low Power Consumption No Latch-Up Same Pin Assignments as uA709
uA748C . . . D OR P PACKAGE uA748M . . . JG PACKAGE (TOP VIEW)
N1/COMP IN ­ IN + VCC ­
1 2 3 4
8 7 6 5
COMP VCC + OUT N2
uA748M . . . U FLAT PACKAGE (TOP VIEW)
description
The uA748 is a general-purpose operational amplifier that offers the same advantages and attractive features as the uA741 except for internal compensation. External compensation can be as simple as a 30-pF capacitor for unity-gain conditions and, when the closed-loop gain is greater than one, can be changed to obtain wider bandwidth or higher slew rate. This circuit features high gain, large differential and common-mode input voltage range, and output short-circuit protection. Input offset-voltage adjustment can be provided by connecting a variable resistor between the offset null pins as shown in Figure 12. The uA748C is characterized for operation from 0°C to 70°C; the uA748M is characterized for operation over the full military temperature range of ­ 55°C to 125°C.
NC N1/COMP IN ­ IN + VCC ­
1 2 3 4 5
10 9 8 7 6
NC COMP VCC + OUT N2
NC ­ No internal connection
symbol
COMP N1/COMP N2
IN +
+ OUT
IN ­
­
AVAILABLE OPTIONS PACKAGE TA 0°C to 70°C ­55°C to 125°C VIO max AT 25°C 8-PIN SMALL OUTLINE (D) CERAMIC DIP (JG) PLASTIC DIP (P) 10-PIN FLAT PACK (U)
6 mV
uA748CD
--
uA748CP
--
5 mV
--
uA748MJG
--
uA747MU
The D package is available taped and reeled. Add the suffix R to the device type,(e.g., uA748CDR).
PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
Copyright © 1990, Texas Instruments Incorporated
POST OFFICE BOX 655303
· DALLAS, TEXAS 75265
1
uA748C, uA748M GENERAL-PURPOSE OPERATIONAL AMPLIFIERS
SLOS095 ­ D921, DECEMBER 1970 ­ REVISED OCTOBER 1990
schematic
IN ­ COMP VCC +
IN +
34 OUT 34
N2
1 k N1/COMP
50 k
1 k VCC ­
Resistor values shown are nominal.
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
uA748C Supply voltage, VCC + (see Note 1) Supply voltage, VCC ­ (see Note 1) Differential input voltage (see Note 2) Input voltage (either input, see Notes 1 and 3) Voltage range between either offset null terminal (N1/N2) and VCC ­ Duration of output short circuit (see Note 4) Continuous total power dissipation Operating free-air temperature range Storage temperature range Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds NOTES: 1. 2. 3. 4. JG or U package D or P package 260 18 ­ 18 ± 30 ± 15 ­ 0.5 to 2 unlimited 0 to 70 ­ 65 to 150 uA748M 22 ­ 22 ± 30 ± 15 ­ 0.5 unlimited ­ 55 to 125 ­ 65 to 150 300 °C °C °C °C UNIT V V V V V
See Dissipation Rating Table
All voltage values, unless otherwise noted, are with respect to the midpoint between VCC + and VCC ­. Differential voltages are at the noninverting input terminal with respect to the inverting input terminal. The magnitude of the input voltage must never exceed the magnitude of the supply voltage or 15V, whichever is less. The output may be shorted to ground or either power supply. For the uA748M only, the unlimited duration of the short circuit applies at (or below) 125°C case temperature or 75°C free-air temperature DISSIPATION RATING TABLE PACKAGE D JG P U TA 25°C POWER RATING 500 mW 500 mW 500 mW 500 mW DERATING FACTOR 5.8 mW/°C 8.4 mW/°C N/A 5.4 mW/°C DERATE ABOVE TA 64°C 90°C N/A 57°C TA = 70°C POWER RATING 464 mW 500 mW 500 mW 432 mW TA = 125°C POWER RATING N/A 210 mW N/A 135 mW
2
POST OFFICE BOX 655303
· DALLAS, TEXAS 75265
uA748C, uA748M GENERAL-PURPOSE OPERATIONAL AMPLIFIERS
SLOS095 ­ D921, DECEMBER 1970 ­ REVISED OCTOBER 1990
electrical characteristics at specified free-air temperature, VCC ± = ±15 V, CC = 30 pF
PARAMETER VIO IIO IIB VICR Input offset voltage offset voltage Input offset current offset current Input bias current bias current Common-mode input voltage range RL= 10 k VO(PP) Maximum peak output voltage swing Large-signal differential voltage amplification Input resistance Output resistance resistance Input capacitance Common-mode rejection ratio Supply-voltage sensitivity (VIO / VCC) Short-circuit output current Supply current current Power dissipation (each amplifier) No load load, No load load, VO = 0 VO = 0 VIC = VICRmin, VO = 0 VCC = ± 9 V to ± 15 V, VO = 0 VO = 0, See Note 5 RL 10 k RL= 2 k RL 2 k AVD ri ro Ci CMRR kSVS RL 2 k, VO = ± 10 V VO = 0 VO = 0 VO = 0 TEST CONDITIONS CONDITIONS 25°C Full range 25°C Full range 25°C Full range 25°C Full range 25°C Full range 25°C Full range 25°C Full range 25°C 25°C 25°C 25°C Full range 25°C Full range 25°C 25°C Full range 25°C Full range 50 ± 25 1.7 70 70 30 150 150 ± 40 2.8 3.3 85 100 50 ± 25 1.7 ± 12 ± 12 ± 12 ± 12 ± 10 ± 10 20 15 0.3 2 75 1.4 90 70 70 30 150 150 ± 40 2.8 3.3 85 100 mA mA mW 200 ± 13 ± 14 ± 13 80 20 uA748C MIN TYP 1 MAX 6 7.5 200 300 500 800 ± 12 ± 12 ± 12 ± 12 ± 10 ± 10 50 25 0.3 2 75 1.4 90 200 V/mV M pF dB ± 13 ± 14 V ± 13 80 20 MIN uA748M TYP 1 MAX 5 6 200 500 500 1500 UNIT mV nA nA V
µV/V
IOS ICC PD
All characteristics are measured under open-loop conditions with zero common-mode input voltage unless otherwise specified. Full range for uA748C is 0°C to 70°C and for uA748M is ­ 55°C to 125°C. NOTE 5: This typical value applies only at frequencies above a few hundred hertz because of the effects of drift and thermal feedback.
operating characteristics, VCC ± = ± 15 V, TA = 25°C
PARAMETER tr SR Rise time Overshoot factor Slew rate at unity gain TEST CONDITIONS VI = 20 mV, RL = 2 k CL = 100 pF CC = 30 pF See Figure 1 20 mV 100 pF, k, 30 pF, See Figure VI = 10 V, RL = 2 k, CL = 100 pF, CC = 30 pF, See Figure 1 MIN TYP 0.3 5% 0.5 V/µs MAX UNIT µs
POST OFFICE BOX 655303
· DALLAS, TEXAS 75265
3