Details, datasheet, quote on part number:VRE120
| |
| Part: | VRE120 |
| Category: | Power Management => Voltage References => Precision |
| Description: | Output (V) = +10, -10, ±10 ;; Initial Error (mV) = 0.5, 0.8, 1.0, 1.5 ;; Temp Error (ppm/oC) = 1.3, 2.2 ;; Noise (µVpp) = 6 ;; Package = DIP14 ;; Feature = High Temp |
| Company: | Thaler Corp. |
| Datasheet: | Download VRE120 datasheet File size : 337 kB |
| Request For quote: | Find where to buy VRE120
|
| |
Datasheet text preview:
VRE120/121/122
Precision High Temperature Reference Supplies
THALER CORPORATION · 2015 N. FORBES BOULEVARD · TUCSON, AZ. 85745 · (520) 882-4000
FEATURES
· WIDE OPERATING RANGE: -55°C TO +180°C · EXTREMELY LOW DRIFT: 1 ppm /°C -55°C to +150°C · LOW WARM-UP DRIFT: 1 ppm Typ. · EXCELLENT STABILITY: 6 ppm / 1000 Hrs. Typ. · EXCELLENT LINE REGULATION: 3 ppm / V Typ. · HERMETIC 14-PIN CERAMIC DIP · PIN & FUNCTION COMPATIBLE WITH AD2700, AD2710, MAX 670/671 REFERENCES
APPLICATIONS
· PRECISION A/D and D/A CONVERTERS · TRANSDUCER EXCITATION · ACCURATE COMPARATOR THRESHOLD REFERENCE · HIGH RESOLUTION SERVO SYSTEMS · DIGITAL VOLTMETERS · HIGH PRECISION TEST and MEASUREMENT INSTRUMENTS · GEOLOGICAL EQUIPMENT
DESCRIPTION
VRE120 series references are designed to operate over an extremely wide temperature range (-55°C to +180°C) and still provide excellent accuracy. The VRE120 provides a +10V output, the VRE121 provides a -10V and the VRE122 provides a ±10V output. All types are available in commercial (C suffix) and military (M suffix) models. The "M" models are screened for high reliability and quality. Two accuracy grades (standard and "A") are available for all models. SELECTION GUIDE
Max. Volt Deviation
(-55°C to +150°C)
Type
Output
Max. Volt Deviation
(150°C to +180°C)
Initial Accuracy (Max)
VRE120C VRE120CA VRE120M VRE120MA
+10V +10V +10V +10V
1.5mV 1.0mV 1.5mV 1.0mV
5.0mV 3.0mV 5.0mV 3.0mV
1.0mV 0.5mV 1.5mV 0.8mV
The adjacent selector guide shows the limits of the VRE121C -10V 1.5mV 5.0mV 1.0mV most important parameters of the VRE120 series VRE121CA -10V 1.0mV 3.0mV 0.5mV voltage references. The maximum voltage VRE121M -10V 1.5mV 5.0mV 1.5mV deviation increases linearly with temperature from VRE121MA -10V 1.0mV 3.0mV 0.8mV the 150°C specification to the 180°C specification. For example, the A grade maximum voltage VRE122C ±10V 1.5mV 5.0mV 1.0mV deviation of 1mV increases to 2mV at 175°C and is VRE122CA ±10V 1.0mV 3.0mV 0.5mV 3mV at 180°C. This degree of accuracy over such VRE122M ±10V 1.5mV 5.0mV 1.5mV a large temperature range has been achieved VRE122MA ±10V 1.0mV 3.0mV 0.8mV using the Thaler Corporation patented multipoint compensation technique. All devices are packaged in 14-pin hermetic ceramic packages for maximum long term stability. They are pin and function compatible with other Thaler references and AD2700, AD2710 and MAX 670/671 References Superior stability, accuracy, and quality make these references ideal for precision applications such as A/D and D/A converters, high-accuracy test and measurement instrumentation, and transducer excitation.
VRE120DS REV. C SEPT 1994
4-56
ELECTRICAL SPECIFICATIONS
Vps =±15V, T = 25°C, RL = 10K unless otherwise noted.
VRE120/121/122
CA
MIN T Y P M A X MIN
MODEL PARAMETERS
MIN
C
T Y P MAX
M
MA UNITS
T Y P M A X MIN T Y P M A X
ABSOLUTE MAXIMUM RATINGS Power Supply ±13.5 ±22 Operating Temperature -55 180 Storage Temperature -65 150 Short Circuit Protection Continuous OUTPUT VOLTAGE VRE120 VRE121 VRE122 OUTPUT VOLTAGE ERRORS Initial Error Warmup Drift (1) -55°C to 150°C (3) 150°C to 180°C Long-Term Stability Noise (.1-10Hz) OUTPUT CURRENT Range REGULATION Line Load OUTPUT ADJUSTMENT Range Temperature Coefficient POWER SUPPLY CURRENTS VRE120 +PS VRE121 -PS VRE122 +PS VRE122 -PS NOTES: *Same as C Models.
(2)
* * * *
* * *
* * * *
* * *
* * * *
* * *
V °C °C
+10 -10 ±10
* * *
* * *
* * *
V V V
1.0 2 1.5 5.0 6 6 * * 1
0.5 2 1.0 3.0 * *
1.5 1 * * * *
0.8 * *
mV ppm mV mV ppm/1000hr. µVpp
±10
*
*
*
mA
3 3
10
* *
*
* *
*
* *
*
ppm/V ppm/mA
10 4
* *
* *
* *
mV µV/°C/mV
5 5 7 4
7 7 9 6
* * * *
* * * *
* * * *
* * * *
* * * *
* * * *
mA mA mA mA
1. Using the box method, the specified value is the maximum deviation from the output voltage at 25°C over the specified operating temperature range. 2. The specified values are unloaded. 3. Cone widening from 150 °C value to specified value.
VRE120DS REV. C SEPT 1994
4-57
TYPICAL PERFORMANCE CURVES
VOUT vs. TEMPERATURE VOUT vs. TEMPERATURE VOUT vs. TEMPERATURE VOUT vs. TEMPERATURE
Temperature oC VRE120/121/122C
Temperature oC VRE120/121/122CA
Temperature oC VRE120/121/122M
Temperature oC VRE120/121/122MA
VRE120/121
QUIESCENT CURRENT VS. TEMP JUNCTION TEMP. RISE VS. OUTPUT CURRENT PSRR VS. FREQUENCY
Temperature oC
Output Current (mA)
Frequency (Hz)
VRE122
POSITIVE OUTPUT QUIESCENT CURRENT VS. TEMP JUNCTION TEMP. RISE VS. OUTPUT CURRENT PSRR VS. FREQUENCY
Temperature oC
Output Current (mA)
NEGATIVE OUTPUT JUNCTION TEMP. RISE VS. OUTPUT CURRENT
Frequency (Hz)
QUIESCENT CURRENT VS. TEMP
PSRR VS. FREQUENCY
Temperature oC
Output Current (mA)
Frequency (Hz)
VRE120DS REV. C SEPT.1994
4-58
|
|