Details, datasheet, quote on part number:307C1287BHMAB
| |
Datasheet text preview:
307C1287BHLAB, 307C1287BHMAB
Vishay Cera-Mite
PTC Thermistors
APPLICATION - STARTING IN ELECTRONIC FLUORESCENT BALLASTS
STANDARD ELECTRICAL SPECIFICATIONS @ 25°C
PARAMETER Resistance Maximum Voltage Maximum Continuous Voltage Withstand Voltage Switching Temperature UNIT Vrms Vrms Vrms °C 150 ± 25% 400 100 600 105
OPERATING TIME (SEC)
GENERAL APPLICATION DIAGRAM
Discharge Tube
10.0
1.0
C
0.1
PTC
Lamp Ignition Time can be optimized to increase life of Discharge Tube
0.2
0.4
0.6
0.8 1 CURRENT (A)
OPERATING TIME TO 50% CURRENT
MECHANICAL SPECIFICATIONS
PARAMETER Wire Coating Packaging Copper Clad Steel None Bulk Pack
DIMENSIONS in millimeters
A B
Diameter Thickness
C
A B C D
8.5 max. 4.5 max. 13.0 max. 34 min. 4.75 ± 0.6
Height Lead Length 307C1287BHLAB 307C1287BHMAB Lead Spacing
D Ø E
E ø
5.0 ± 0.8 0.51
Lead Diameter
Document Number: 23027 Revision 19-Apr-01
ceramite.support@vishay.com
www.vishay.com 1
|
|