Details, datasheet, quote on part number:3302
| |
| Part: | 3302 |
| Category: | Discrete => Diodes & Rectifiers => Rectifier Diodes => Assemblies |
| Description: | |
| Company: | Voltage Multipliers, Inc. |
| Datasheet: | Download 3302 datasheet File size : 239 kB |
| Request For quote: | Find where to buy 3302
|
| |
Datasheet text preview:
200 V - 1,000 V Three Phase Bridge
9.0 A - 10.0 A Forward Current 70 ns - 3000 ns Recovery Time
3302 - 3310 3302F - 3310F 3302UF - 3310UF
ELECTRICAL CHARACTERISTICS AND MAXIMUM RATINGS
Part Number Working Reverse Voltage (Vrwm) Average Rectified Current @TC (Io) 55°C Volts 3302 3306 3310 3302F 3306F 3310F 3302UF 3306UF 3310UF Amps 100°C Amps Reverse Current @ Vrwm (Ir) 25°C µA 100°C µA 25°C Volts Amps Forward Voltage 1 Cycle Surge Current tp=8.3ms (Ifsm) 25°C Amps Repetitive Surge Current (Ifrm) 25°C Amps Reverse Recovery Time (1) (Trr) 25°C ns °C / W Thermal Impd.
(Vf)
uJ-C
200 600 1000 200 600 1000 200 600 1000
10.0 10.0 10.0 10.0 10.0 10.0 9.0 9.0 9.0
7.0 7.0 7.0 7.0 7.0 7.0 6.5 6.5 6.5
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
25 25 25 25 25 25 25 25 25
1.1 1.1 1.2 1.2 1.5 1.5 1.7 1.7 1.7
3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0
100 100 100 100 100 100 100 100 100
25 25 25 20 20 20 20 20 20
3000 3000 3000 150 150 150 70 70 70
4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2 4.2
(1)Trr Testing: If=0.5A, Ir=1.0A, Irr=0.25A *Op. Temp. & Stg. Temp. = -55°C to +150°C Isolation Voltage: 1500V
1.25(31.75)
_
.75 (19.05)
.38(9.65)
.22(5.59)
11
.31 (7.87) AC AC AC _ +
4-40 THRU (2 PL) .19(4.8) (2 PL) .31(7.9) .25(6.35) .094(2.39)
AC AC AC
Aluminum Case .28(7.11)
+
.45(11.43) MAX.
1.062(27.0)
Dimensions: In. (mm) · All temperatures are ambient unless otherwise noted. · Data subject to change without notice.
VOLTAGE MULTIPLIERS INC. 8711 W. Roosevelt Ave. Visalia, CA 93291
TEL 559-651-1402 FAX 559-651-0740 www.voltagemultipliers.com
255
3302 - 3310 · 3302F - 3310F · 3302UF - 3310UF
12 10 Maximum Current (I) Forward Voltage (V)
3300-F
MAXIMUM FORWARD CURRENT VS. TEMPERATURE
2.3 2.1 1.9 1.7 1.5 1.3
TYPICAL FORWARD VOLTAGE VS. FORWARD CURRENT AT 25°C
8 6 4 2
3300UF
3306-10F 3300UF
3302F
1.1 0.9 0.7
3300
0 25 50 75 100 125 Temperature (C) Ambient Temperature (°C) 150
0.5 0 3 6 9 Forward Current (A) 12 15
1000
REVERSE CURRENT VS. TEMPERATURE AT Vrwm
Reverse Current (uA)
100
10
1 25 50 75 100 Temperatture (°C) a ure (C) 125 150
256
|
|