Datasheet text preview:
New Industry Features
Programmable time sequencing Integrated oscillator and dividers No crystal required Quad voltage monitors Remote delay selection Remote monitor/switch diagnostics Cascade delays of multiple devices
X80140/41/42/43/44
Voltage Supervisor/Sequencer
Quad Programmable Time Delay with Local/ Remote Voltage Monitors
· · · · · · 100 ms to 5 secs Selectable Delay Switches ATE or Data Acquisition Timing Applications Datapath/Memory Timing Applications Data Pipeline Timing Applications Batch Timer/Sequencers Adjustable Duty Cycle Applications
FEATURES · Quad voltage Monitor and Sequencing -- Four independent voltage monitors -- Four time delay circuits (in circuit programmable) -- Remote delay via SMBus -- Factory Programmable voltage thresholds -- Sequence up to 5 power supplies. · Fault detection register -- Remote diagnostics of voltage fail event. · Debounced manual reset input · Manufacturing/Configuration Memory -- 2Kbits of EEPROM -- 400kHz SMBus interface · Available packages -- 20-lead Quad No-Lead Frame (QFN -- 5 x 5 mm) APPLICATIONS · · · · · · · · · · · General Purpose Timers Long Time Delay Generation Cycle Timers / Waveform Generation ON/OFF Delay Timers Supply Sequencing for Distributed Power Programmable Delay Event Sequencing Multiple DC-DC ON/OFF Sequencing Voltage Window Monitoring with Reset ON/OFF switches with Programmable Delay Voltage Supervisor with Programmable Output Delays Databus Power Sequencing
DESCRIPTION The X80140 is a voltage supervisor/sequencer with four built in voltage monitors. This allows the designer to monitor up to four voltages and sequence up to five events. Low voltage detection circuitry protects the system from power supply failure or "brown out" conditions, resetting the system and resequencing the voltages when any of the monitored inputs fall below the minimum threshold level. The RESET pin is active until all monitored voltages reach proper operating levels and stabilize for a selectable period of time. Five common low voltage combinations are available, however, Xicor's unique circuits allow the any voltage monitor threshold to be reprogrammed for special needs or for applications requiring higher precision. A manual reset input provides debounce circuitry for minimum reset component count. Activating the manual reset both controls the RESET output and resequences the supplies through control of the ViGDO pins. The X80140 has 2kb of EEPROM for system configuration, manufacturing or maintenance information. This memory is protected to prevent inadvertent changes to the contents.
BLOCK DIAGRAM RESET SDA
Bus Interface
VSS
VCC MR
POR
Reset Logic and Delay
Control and Fault Registers
SCL WP A0 A1
VP
VMON Logic OSC Divider
Reset
EEPROM 2kbits 4
VSS
V1MON
VREF1
V1GDO
4
Select 0.1s 0.5s 1s 5s
V2GDO V3GDO V4GDO
V2MON
VREF2
delay1 delay2
V3MON
VREF3
delay3 delay4
Delay circuit repeated 4 times
V4MON
VREF4
VSS
REV 1.3.10 3/31/03
VSS
www.xicor.com
Characteristics subject to change without notice
1 of 18
X80140/41/42/43/44 Preliminary Information
PIN OUTS QFN package (Top view) ORDERING INFORMATION ORDER NUMBER VREF1 X80140Q20I 4.5 X80141Q20I 4.5 X80142Q20I 3.0 X80143Q20I 3.0 X80144Q20I 2.25 VREF2 3.0 2.25 2.25 2.25 2.25 VREF3 2.25 0.9 1.7 0.9 0.9 VREF4 0.9 0.9 0.9 0.9 0.9 Package QFN QFN QFN QFN QFN
VCC
VSS
20 19 18 17 16 V4GDO V4MON V3GDO V3MON V2GDO 1 2 3 4 5 6 7 8 9 10 15 14 WP RESET V1GDO V1MON SCL
(5mm x 5mm)
NC
MR 13 12 11 SDA
A0 V2MON
ABSOLUTE MAXIMUM RATINGS
DNC
VP
A1
COMMENT Stresses above those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. This is a stress rating only; functional operation of the device (at these or any other conditions above those listed in the operational sections of this specification) is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. RECOMMENDED OPERATING CONDITIONS Temperature Industrial (I) Min. 40°C Supply Voltage VCC = 4.5 to 5.5V Max. +85°C
Temperature under bias .......... 65°C to +135°C Storage temperature ...... 65°C to +150°C ViMON pins (i = 1 to 4) ........ 5.5V ViGDO pins (i = 1 to 4) ....... 5.5V RESET pin .. 5.5V SDA, SCL, WP, A0, A1 pins .......... 5.5V MR pin......... 5.5V VP pin ........... 14V D.C. output current ..... 5mA Lead temperature (soldering, 10 seconds)........ 300°C
ELECTRICAL CHARACTERISTICS (Standard Settings) (Over the recommended operating conditions unless otherwise specified). Symbol Parameter Min. 4.5 1.0 9 Typ. Max. 5.5 2.5 12 10 10 15 Unit Test Conditions
DC Characteristics Supply Operating Range VCC ICC Supply Current VP(3) EEPROM programming voltage IP Programming Current ILI Input Leakage Current (MR) ILO Output Leakage Current (V1GDO, V2GDO, V3GDO, V4GDO, RESET) Input LOW Voltage (MR) VIL VIH Input HIGH Voltage (MR) VOL Output LOW Voltage (RESET, V1GDO, V2GDO, V3GDO, V4GDO)
REV 1.3.10 3/31/03
V mA fSCL = 0 kHz V mA µA VIL = GND to VCC µA
-0.5 5 x 0.7
5 x 0.3 5.5 0.4
V V V
IOL = 4.0 mA
www.xicor.com
Characteristics subject to change without notice
2 of 18
X80140/41/42/43/44 Preliminary Information
ELECTRICAL CHARACTERISTICS (Continued)(Standard Settings) (Over the recommended operating conditions unless otherwise specified). Symbol COUT(1) Parameter Output Capacitance (RESET, V1GDO, V2GDO, V3GDO, V4GDO) V1MON Trip Point Voltage (Range) Min. Typ. Max. 8 Unit Test Conditions pF VOUT = 0V
VREF1
X80140 X80141 X80142 X80143 X80144
VREF2 V2MON Trip Point Voltage
X80140 X80141 X80142 X80143 X80144
VREF3 V3MON Trip Point Voltage
X80140 X80141 X80142 X80143 X80144
VREF4 VREF V4MON Trip Point Voltage
All Devices
Voltage Reference Long Term Drift AC Characteristics tMR(3) Minimum time high for reset valid on the MR pin Delay from MR enable to tMRE(3) V1GDO HIGH tRESET_E(3) Delay from ViGDO to RESET valid LOW tDPOR(3) Internal Device Delay on power up tTO(3) ViGDO turn off time
2.20 4.45 4.45 2.95 2.95 2.20 2.20 2.95 2.20 2.20 2.20 2.20 0.85 2.20 0.85 1.65 0.85 0.85 0.85 0.85 0 5
4.50 4.50 3.00 3.00 2.25 3.00 2.25 2.25 2.25 2.25 2.25 0.90 1.70 0.90 0.90 0.90
4.70 4.55 4.55 3.05 3.05 2.30 4.70 3.05 2.30 2.30 2.30 2.30 3.5 2.30 0.95 1.75 0.95 0.95 3.5 0.95 -100
V
V
V
V mV 10 years µs
1.6 1 45 50 50 55
µs µs ms ns
ELECTRICAL CHARACTERISTICS (Programmable Parameters) (Over the recommended operating conditions unless otherwise specified). Symbol tSPOR Parameter Delay before RESET assertion TPOR1 = 0 TPOR0 = 0 TPOR1 = 0 TPOR0 = 1 TPOR1 = 1 TPOR0 = 0 TPOR1 = 1 TPOR0 = 1 Time Delay used in Power Sequencing (i = 1 to 4) TiD1 = 0 TiD0 = 0 TiD1 = 0 TiD0 = 1 TiD1 = 1 TiD0 = 0 TiD1 = 1 TiD0 = 1 Min. 90 450 0.9 4.5 Typ. 100 500 1 5 Max. 110 550 1.1 5.5 Unit ms ms s s Test Conditions Factory Default (3) (3) (3)
tDELAYi
90 450 0.9 4.5
100 500 1 5
110 550 1.1 5.5
ms ms s s
Factory Default (3) (3) (3)
REV 1.3.10 3/31/03
www.xicor.com
Characteristics subject to change without notice
3 of 18
|
|