Details, datasheet, quote on part number:HS-101
| |
Datasheet text preview:
Reflective sensors
HS-101
DIMENSIONS
HS-101 are reflection sensors which aim at the human b o d y detection such as ATM. HS-101 has high resistance to ambient light by using modulated light. HS-101 are installed with a screw and also can be connected very easily with 3 pin connector.
(Unit : mm)
FEATURES
¶U ompact C ¶U3pin connector type
APPLICATIONS
¶UHuman body detection for ATM etc
MAXIMUM RATINGS
Item
Supply voltage *1 Output voltage *2 Low level output current *3*4 Operating temp. *3* Storage temp.4
(Ta=2°...) 5
Symbol
VCC VO O IL Topr. Tstg.
Rating
5.5 28 30 £ 0 £60 1° ´ £ 0 £70 2° ´
Unit
V V mA °... °...
*1. C-E voltage for output transistor *2. Collector current for output transistor *3. No icebound or dew *4. The connector shall be inserted or pulled out at normal temperature.
ELECTRO-OPTICAL CHARACTERISTICS
Item Symbol
VCC C IC VOL VOH LHL V EVLH/EHL t EVS EVT EVW
(Ta=2°...) 5
Conditions
L= detecting O=5V, R 1k ÿ V · L= · non detectingO=5V,R 1k ÿ V reflection rate 90%, OFF°ÊON 30cm°ø 30cm reflection rate 90%, 30cm°ø 30cm reflection rate 90%, L=50cm, 30cm°ø 30cm
Min. Typ.
4.75 4.5 50 5 6.5 100 85 100
Max.
5.25 12 0.2 150 200 V mA V V cm % ms lx lx lx
Unit.
10,000 Luminous intensity at sensing area3,000 3,000
- 1-
Reflective sensors
HS-101
Detection area characteristics (VCC=5V, Ta=25°£) C
Detection length / Ambient temp.chracteristics