Digchip : Database on electronics components
Electronic components database
Search:                      In section:
Member, Distributor  
Log In
Email:
Password:

Details, datasheet, quote on part number:OS-LM10A-W1-854
 
 
Part:OS-LM10A-W1-854
Category:Optoelectronics => Display => LEDs => LINEARlight Flex
Description:Linearlight Flex With 600 Topled, White
Company:Osram Opto Semiconductors
Datasheet:Download OS-LM10A-W1-854 datasheet   File size : 167 kB
Request For quote:  Find where to buy OS-LM10A-W1-854
 



Datasheet text preview:
Data Sheet
LINEARlight flex
OS-LM10A
Benefits
Ø
Linear separable LED strip on flexible printed circuit board with self-adhesive back Small height Available in various colors Minimal heat generation
Ø Ø Ø
Applications
Ø
Edge-lighting of transparent or diffused materials Path & contour marking Illuminated signs Walkways
Ø Ø Ø
Technical Operating Data
Product OS-LM10A-W1-854 OS-LM10A-W1-847 OS-LM10A-A OS-LM10A-Y1 OS-LM10A-T1 OS-LM10A-B1 Color white white red yellow green blue N u m b e r of LEDs 600 600 600 600 600 600 Voltage [V DC]* 24 24 24 24 24 24 Power [W]* 57,6 57,6 72,0 72,0 72,0 72,0 C u r r e n t Radiance [A]* Angle [°]* 2,4 2,4 3 3 3 3 120 120 120 120 120 120 W a v e l e n g t h [nm] Color Temp [K]* 5400 K 4700 K 617 nm 587 nm 525 nm 469 nm L u m . Flux [lm]* 540 540 930 1290 675 170
*) All Data are related to the entire module
Due to the special conditions of the manufacturing processes of LED the typical data of technical parameters can only reflect statistical figures and do not necessarily correspond to the actual parameters of each single product which could differ from the typical data.
Technical Features
Ø Modules optimized for use with OSRAM Ø Entire Module consists of 600 LEDs Ø W i d e viewing angle enables homogeneously
OPTOTRONIC power supplies.
Ø Dimmable by Pulse width modulation (PWM)
with the electronic controller OT DIM
Ø Smallest unit of 10 LEDs can be cut out at
illuminated surfaces
Ø Size of printed circuit board ( LxWxH): 8400 mm
regular intervals without damaging the rest of the module
x 10 mm x 3 mm
Ø Size of smallest unit 10 LED
(LxW): 140 mm x 10 mm
OS-LM10A -
Seite 1 von 4
Minimum and Maximum Ratings
Product OS-LM10A-W1-854 OS-LM10A-W1-847 OS-LM10A-A OS-LM10A-Y1 OS-LM10A-T1 OS-LM10A-B1 O p e r a t i n g Temperature at Tc-Point [ °C ] * - 3 0 ... 7 5 - 3 0 ... 7 5 - 3 0 ... 8 5 - 3 0 ... 8 5 - 3 0 ... 7 5 - 3 0 ... 7 5 S t o r a g e Temperature [ °C ] * - 4 0 ... 8 5 - 4 0 ... 8 5 - 4 0 ... 8 5 - 4 0 ... 8 5 - 4 0 ... 8 5 - 4 0 ... 8 5 V o l t a g e Range [ V dc ] * 2 3 ... 2 5 2 3 ... 2 5 2 3 ... 2 5 2 3 ... 2 5 2 3 ... 2 5 2 3 ... 2 5 R e v e r s e Voltage [ V dc ] * 25 25 25 25 25 25
*) Exceeding maximum ratings for operation and storage temperature will reduce expected life time or destroy the LED Module.
Exceeding maximum ratings for operation voltage will cause hazardous overload and will likely destroy the LED Module. The temperature of the LED module has to measured at the Tc-point according to EN60598-1 in a thermally constant status with a temperature sensor or a temperature sensitive label (available e.g. at RS-Components). For exact location of the Tc-point see drawing below.
Drawing
OS-LM10A -
Seite 2 von 4
Safety Information
Ø The LED module itself and all its components may not be mechanical stressed. Ø Assembly must not damage or destroy conducting paths on the circuit board.
The LED Module incorporates no protection against: Short circuits, Overload, Overheating. Therefore it is absolutely necessary to operate the modules with a electronically stabilised power supply offering protection against the above mentioned safety risks. For dimming applications attention should be paid to specific references in "OPTOTRONIC Technical Guide".
OSRAM OPTOTRONIC power supplies are specifically designed with the necessary protection features for safe operation.
When using other power supplies other than OPTOTRONIC the following basic safety features are required, in addition to any other application specific concerns and local safety codes: Ø Ø Ø Ø Short circuit protection Overload protection Overheat protection Correct output voltage
Ø Correct electrical polarity needs to be observed. Wrong polarity will result in no light emission. Ø Parallel connection is highly recommended as safe electrical operation mode. Serial connection is not recommended. Unbalanced voltage drop can cause hazardous overload and demage the LED module. Ø Installation of LED modules (with power supplies) needs to be made with regard to all applicable electrical and safety standards. Only qualified personnel should be allowed to perform installations. Ø Please ensure that the power supply is of adequate power to operate the total load. Ø At mounting on metallic surfaces there have to be a electrical isolation at soldering points between module and the mounting surface. Ø The maximum length of LINEARlight Flex OS-LM10A is 4200 mm with power feed at one end. The complete module 8400 mm can be operated with a two pole power feed in the middle of the module or from both ends, when do you use one power supply. Ø Pay attention to ESD steps when mounting the module Ø The module, as manufactured, has no conformal coating and therefore offers no inherent protection against corrosion. The ability to customize the length of the module by cutting at specifically marked points is a key feature of the product and hence the reason for no factory installed conformal coating. For these reasons, it is recommended that the user complete all module modifications first ( cutting, wiring) and then apply a conformal coating in the final stages of installation. Ø Damage by corrosion will not be honored as a materials defect claim. It is the user´s responsibility to provide suitable protection against corrosive agents such as moisture and condensation and other harmful elements. Ø For applications involving exposure to humidity and dust the module must be protected by a fixture or housing with a suitable protection class. The module can be protected against condensation water by treatment with an appropriate circuit board grade conformal coating. The conformal coating should have the following features: - Optical transparency - UV-resistance - thermal expansion matching the thermal expansion of the module 15-30*10^-6 cm/cm/K - low permeability of steam for all climatic conditions - resistance against corrosive environment The lacquer APL of the company Electrolube http://www.electrolube.com met the conditions for the LINEARlight Flex in our tests.
OS-LM10A -
Seite 3 von 4