Details, datasheet, quote on part number:TPS334L106
| |
Datasheet text preview:
Lighting
|
Imaging
|
Telecom
Thermopile Infrared Detectors
Thermopile Detector TPS 334 L10.6
New: Integrated silicon lens Small spot size: distance spot size ratio: D:S = 11:1 For industrial remote temperature measurement applications
The TPS 334 L10.6 detector extends the features of the TPS 334 through an integrated micromachined silicon lens optics. In TO 5 type housing it employs a chip of 0.7 x 0.7 mm2 absorber size with a 30 kV thermistor as temperature reference and a lens with 10.6 mm focal length. An inlay in the housing suppresses reflections at the cap. The lens is not coated, but if a restricted wavelength region is desired (e.g. 8..14 mm), it is possible to equip the inlay with an additional filter (e.g. G9). The sensor shows a flat sensitivity characteristics over the wavelength.
Parameters
p
DATASHEET
TP S
typical
334 L10.6
units condition
S ensitive area Window size DC sensitivity R esistance Noise NEP D*
Right for modification reserved / WS /, 21.5.2001
0.7 x 0.7 5.5 75 75 21 0.28 1.6 x 108
mm2 mm V /W kW nV /Ö Hz
absorbi ng area diameter 500K BB w/o optics
r.m.s. 300K ,
nW/Ö Hz 500K BB w/o optics cmÖ Hz/W 500K BB w/o optics
TC of sensitivity TC of resistance Time constant S torage temperature
0.02 0.02 25 -40 100 100 30 3964 5
%/K %/K ms °C °C kW K ° non permanent non permanent 25°C 25°C /100°C at 50% poi nts
Operating temperature -40 Thermistor resistance beta Field of view
1.0 TPS 334 Relative signal output 0.8 0.6 0.4 0.2 -3 dB level
1
10 Frequency in Hz
100
Dimensions in mm Asia: PerkinElmer Optoelectronics 47, Ayer Rajah Crescent #06-12 Singapore 139947 Phone +65 775 2022 Fax +65 775 1008
Europe: PerkinElmer Optoelectronics GmbH Wenzel Jaksch Str 31 Wiesbaden / Germany Phone +49(0)611 492 0 Fa x +49(0)611 492 170
USA: PerkinElmer Optoelectronics 2175 Mission Colledge Blvd Santa Clara, CA 95054 Phone +408 565 0830 Fax +408 565 0703
www.perkinelmer.com/opto
|
|